SM-2601F Link Protector

 






 
 

horizontal rule

The SM-2601F Intelligent Fiber Link Protector provides a fully managed automatic link backup capability to "mission-critical" 1000BaseSX or 1000BaseLX Fiber Ethernet links. Protects vital connections to servers, routers, and other key devices that require fail-safe operation. The SM-2601F operates by monitoring a "primary" link and, in the event of a failure, automatically switches to the backup link. The Link Protector does not require any additional network cards in a server and does not require router-level switchovers if a failure occurs. The backup link can be connected to either another port on a switch or an entirely different switch for greater protection. The unit contains a dual Mode Protected Port (one LC Fiber and one RJ45 Copper) for a redundant station port configuration. The unit also functions in a back-to-back configuration for redundant cable path applications.

Key Benefits

bulletAutomatic or SNMP-based Switching Capability Between Primary and Backup Links
bulletNon-Intrusive Monitoring of Primary and Backup Network Connections
bulletAutomatic Switching in the Event of Link Failure
bulletAdditional Copper 1000BaseT Port for Server Redundancy
bulletRedundant 48VDC and/or 100/220VAC Power

horizontal rule

PRODUCT DESCRIPTION

The SM-2601F Intelligent Fiber Link Protector provides a fully managed automatic link backup capability to "mission-critical" 1000BaseSX or 1000BaseLX Fiber Ethernet links. Protects vital connections to servers, routers, and other key devices that require fail-safe operation. The SM-2601F operates by monitoring a "primary" link and, in the event of a failure, automatically switches to the backup link. The Link Protector does not require any additional network cards in a server and does not require router-level switchovers if a failure occurs. The backup link can be connected to either another port on a switch or an entirely different switch for greater protection. The unit contains a dual Mode Protected Port (one LC Fiber and one RJ45 Copper) for a redundant station port configuration. The unit also functions in a back-to-back configuration for redundant cable path applications.

FEATURES

bulletAutomatic Switching to Backup Link Can Be Programmed To Occur Within 20 to 1100 Milliseconds to Avoid Protocol-Timeouts
bulletAutomatic Switch-Back to Primary Link on Restoration of Service
bulletAutomatic Switching upon Detection of Remote Faults (IEEE 802.3z)
bulletDelayed Switching to Accommodate Slow Boot Switching Hubs
bulletDual Mode Protected Station Port for either LC Fiber or RJ45 Ethernet Connectivity
bulletAlarm on Loss of Primary, Backup and/or Server Links
bulletTelnet Access to Control, Status, and Setup Information
bulletBOOTP Automatic Network Address Recovery
bullet"Ping"-able using ICMP
bulletSNMP MIB II Compliant (RFCs 1155, 1157, 1213)
bulletSNMP Trap Message on Alarm for Link Failure Notification
bulletOutbound Generation of Link Signals to avoid False Alarms on Inactive Links
bulletManual Override for Forced Switching
bulletMultiple LED Indicators for Status Display and Mode Display
bulletJumperless System Configuration Stored in Non-Volatile Memory
bulletRS232 Console Port for Feature Programming
bulletUser Upgradeable Flash Memory for Future Feature Updates
bulletDual Redundant Power Supplies for High Reliability
bulletDual Separate 120V/240V AC Power Inputs(Optional)
bulletDual 48V DC Power Available (Optional)
bullet19" Rackmountable in pairs (1u space requirement)
bulletSX or Optional LX (long range) Ports

APPLICATIONS

bulletProvide Automatic Backup for Critical 1000BaseSX or 1000BaseLX and/or 1000BaseTX Links to Servers, Routers, and other Vital Equipment
bulletProtect Against Failures of Primary Link Due to Cable Cuts, Disconnected Cables, and Hub/Switch Failures from Malfunctioning Ports, Plug-in Cards, or Power Supplies
bulletProvide Backup for Dual NIC Station Port (Servers) Configuration
bulletAdd Redundant Network Wiring in conjunction with other Shore Microsystems Link Protector products
bulletAdd Back to Back Installation of SM-2601F for Enhanced Redundancy and Control
bulletProvide Real Time Automatic Switching for Enhanced Network Uptime
bulletAllow for Prime Time Network Maintenance
bulletProvide Immediate Notification via SNMP of Link Failures
bulletControl Network Configuration/Topology via SNMP Scripts

 

 

 

 

SPECIFICATIONS

bulletStandards: IEEE 802.3z 1000BaseSX or 1000BaseLX and 1000BaseTX
bulletConnectors: Three 1000Base SX or LX, LC Fiber Jacks: One Primary, One Backup, One Direct Station Connection (Server Port); One RJ45 1000BaseTX Twisted Pair Jack as a Direct Station Connection (Server Port); One RJ45 10BaseT Twisted Pair Jack management port, One DB9F DCE RS232 Serial Port; AC: One or Two IEC320; DC: 1 or 2 #6 Screw Lug Mount.
bulletPower Requirements: (2) 110/220V 50/60HzAC or (2) 48V DC or one of each , 15W
bulletSize: 8.5" x 9.0" x 1.75"
bulletApprovals: FCC Part 15 Class A Compliant

 

 

 

 

For Sales enquiry, please send email to sales@sstl.com.hk, or call us at +852 2152 8966.

 
web hit counter HSBC Purchasing Card

We Accept

 HSBC Purchasing Card

&

Citibank Purchasing Card

Contact us for details

Send mail to support@sstl.com.hk with questions or comments about this web site.
Last modified: 09/13/13