![horizontal rule](_themes/pixel/pixrule.gif)
The SM-2601F Intelligent Fiber Link Protector provides a
fully managed automatic link backup capability to "mission-critical"
1000BaseSX or 1000BaseLX Fiber Ethernet links. Protects vital connections to
servers, routers, and other key devices that require fail-safe operation.
The SM-2601F operates by monitoring a "primary" link and, in the event of a
failure, automatically switches to the backup link. The Link Protector does
not require any additional network cards in a server and does not require
router-level switchovers if a failure occurs. The backup link can be
connected to either another port on a switch or an entirely different switch
for greater protection. The unit contains a dual Mode Protected Port (one LC
Fiber and one RJ45 Copper) for a redundant station port configuration. The
unit also functions in a back-to-back configuration for redundant cable path
applications.
Key Benefits
![bullet](_themes/pixel/pixbul1.gif) | Automatic or SNMP-based Switching Capability Between Primary and
Backup Links |
![bullet](_themes/pixel/pixbul1.gif) | Non-Intrusive Monitoring of Primary and Backup Network Connections |
![bullet](_themes/pixel/pixbul1.gif) | Automatic Switching in the Event of Link Failure |
![bullet](_themes/pixel/pixbul1.gif) | Additional Copper 1000BaseT Port for Server Redundancy |
![bullet](_themes/pixel/pixbul1.gif) | Redundant 48VDC and/or 100/220VAC Power |
![horizontal rule](_themes/pixel/pixrule.gif)
![](2601fdia.gif)
PRODUCT DESCRIPTION
The SM-2601F Intelligent Fiber Link Protector provides a fully managed
automatic link backup capability to "mission-critical" 1000BaseSX or
1000BaseLX Fiber Ethernet links. Protects vital connections to servers,
routers, and other key devices that require fail-safe operation. The
SM-2601F operates by monitoring a "primary" link and, in the event of a
failure, automatically switches to the backup link. The Link Protector does
not require any additional network cards in a server and does not require
router-level switchovers if a failure occurs. The backup link can be
connected to either another port on a switch or an entirely different switch
for greater protection. The unit contains a dual Mode Protected Port (one LC
Fiber and one RJ45 Copper) for a redundant station port configuration. The
unit also functions in a back-to-back configuration for redundant cable path
applications.
FEATURES
![bullet](_themes/pixel/pixbul1.gif) | Automatic Switching to Backup Link Can Be Programmed To
Occur Within 20 to 1100 Milliseconds to Avoid Protocol-Timeouts |
![bullet](_themes/pixel/pixbul1.gif) | Automatic Switch-Back to Primary Link on Restoration of
Service |
![bullet](_themes/pixel/pixbul1.gif) | Automatic Switching upon Detection of Remote Faults
(IEEE 802.3z) |
![bullet](_themes/pixel/pixbul1.gif) | Delayed Switching to Accommodate Slow Boot Switching
Hubs |
![bullet](_themes/pixel/pixbul1.gif) | Dual Mode Protected Station Port for either LC Fiber or
RJ45 Ethernet Connectivity |
![bullet](_themes/pixel/pixbul1.gif) | Alarm on Loss of Primary, Backup and/or Server Links |
![bullet](_themes/pixel/pixbul1.gif) | Telnet Access to Control, Status, and Setup Information |
![bullet](_themes/pixel/pixbul1.gif) | BOOTP Automatic Network Address Recovery |
![bullet](_themes/pixel/pixbul1.gif) | "Ping"-able using ICMP |
![bullet](_themes/pixel/pixbul1.gif) | SNMP MIB II Compliant (RFCs 1155, 1157, 1213) |
![bullet](_themes/pixel/pixbul1.gif) | SNMP Trap Message on Alarm for Link Failure
Notification |
![bullet](_themes/pixel/pixbul1.gif) | Outbound Generation of Link Signals to avoid False
Alarms on Inactive Links |
![bullet](_themes/pixel/pixbul1.gif) | Manual Override for Forced Switching |
![bullet](_themes/pixel/pixbul1.gif) | Multiple LED Indicators for Status Display and Mode
Display |
![bullet](_themes/pixel/pixbul1.gif) | Jumperless System Configuration Stored in Non-Volatile
Memory |
![bullet](_themes/pixel/pixbul1.gif) | RS232 Console Port for Feature Programming |
![bullet](_themes/pixel/pixbul1.gif) | User Upgradeable Flash Memory for Future Feature
Updates |
![bullet](_themes/pixel/pixbul1.gif) | Dual Redundant Power Supplies for High Reliability |
![bullet](_themes/pixel/pixbul1.gif) | Dual Separate 120V/240V AC Power Inputs(Optional) |
![bullet](_themes/pixel/pixbul1.gif) | Dual 48V DC Power Available (Optional) |
![bullet](_themes/pixel/pixbul1.gif) | 19" Rackmountable in pairs (1u space requirement) |
![bullet](_themes/pixel/pixbul1.gif) | SX or Optional LX (long range) Ports |
APPLICATIONS
![bullet](_themes/pixel/pixbul1.gif) | Provide Automatic Backup for Critical 1000BaseSX or
1000BaseLX and/or 1000BaseTX Links to Servers, Routers, and other Vital
Equipment |
![bullet](_themes/pixel/pixbul1.gif) | Protect Against Failures of Primary Link Due to Cable
Cuts, Disconnected Cables, and Hub/Switch Failures from Malfunctioning
Ports, Plug-in Cards, or Power Supplies |
![bullet](_themes/pixel/pixbul1.gif) | Provide Backup for Dual NIC Station Port (Servers)
Configuration |
![bullet](_themes/pixel/pixbul1.gif) | Add Redundant Network Wiring in conjunction with other
Shore Microsystems Link Protector products |
![bullet](_themes/pixel/pixbul1.gif) | Add Back to Back Installation of SM-2601F for Enhanced
Redundancy and Control |
![bullet](_themes/pixel/pixbul1.gif) | Provide Real Time Automatic Switching for Enhanced
Network Uptime |
![bullet](_themes/pixel/pixbul1.gif) | Allow for Prime Time Network Maintenance |
![bullet](_themes/pixel/pixbul1.gif) | Provide Immediate Notification via SNMP of Link
Failures |
![bullet](_themes/pixel/pixbul1.gif) | Control Network Configuration/Topology via SNMP Scripts |
![](2601Fds_fig1.gif)
SPECIFICATIONS
![bullet](_themes/pixel/pixbul1.gif) | Standards: IEEE 802.3z 1000BaseSX or 1000BaseLX and 1000BaseTX |
![bullet](_themes/pixel/pixbul1.gif) | Connectors: Three 1000Base SX or LX, LC Fiber Jacks: One Primary, One
Backup, One Direct Station Connection (Server Port); One RJ45 1000BaseTX
Twisted Pair Jack as a Direct Station Connection (Server Port); One RJ45
10BaseT Twisted Pair Jack management port, One DB9F DCE RS232 Serial Port;
AC: One or Two IEC320; DC: 1 or 2 #6 Screw Lug Mount. |
![bullet](_themes/pixel/pixbul1.gif) | Power Requirements: (2) 110/220V 50/60HzAC or (2) 48V DC or one of
each , 15W |
![bullet](_themes/pixel/pixbul1.gif) | Size: 8.5" x 9.0" x 1.75" |
![bullet](_themes/pixel/pixbul1.gif) | Approvals: FCC Part 15 Class A Compliant |
|
|